LABORATORY
More than 10 years of experience in the market.
Our Metrology Laboratory has more than 10 years of experience in the market, satisfying the needs of our customers metrological control.
We seek to be a strategic ally for the industry by providing the most comprehensive range of accredited facilities and the best attention by our technical team. Currently the metrology laboratory is accredited in the magnitudes of force, mass, length and Scales, Torsional torque, temperature and pressure.
Masses and Balances – Length – Pressure – Strength – Torsional torque – Temperature
Masses and Balances
MASSES
Instrument to Calibrate | Measurement Range | Standard Document | |
---|---|---|---|
Weight Class Set M1, M2, M3 | 1 mg a 20 kg | NTC 1848 | |
Weight Class Set F1, F2 | 1 g a 1 kg | NTC 1848 |
Balances
Instrument to Calibrate | Measurement Range | Standard Document | |
---|---|---|---|
Non-automatic weighing instruments with d ≥ 0,01 mg | 0 g a 210 g | Guide SIM MWG7/gc-01 | |
Non-automatic weighing instruments with d ≥ 1 mg | 0 g a 1 kg | Guide SIM MWG7/gc-01 | |
Non-automatic weighing instruments with d ≥ 0,01 g | 0 g a 10 kg | Guide SIM MWG7/gc-01 | |
Non-automatic weighing instruments with d ≥ 0,1 g | 0 g a 30 kg | Guide SIM MWG7/gc-01 | |
Non-automatic weighing instruments with d ≥ 20 g | 0 g a 100 kg | Guide SIM MWG7/gc-01 | |
Non-automatic weighing instruments with d ≥ 50 g, con d ≥ 100 g | 0 g a 500 kg | Guide SIM MWG7/gc-01 | |
Non-automatic weighing instruments with d ≥ 100 g | 0 g a 5 000 kg | Guide SIM MWG7/gc-01 |
LENGTH
Instrument to Calibrate | Measurement Range | Standard Document | |
---|---|---|---|
Pie de Rey (Outside measurement, interior, depth) Digital display, circular or vernier, d ≥ 0,01 mm | 0 mm a 300 mm | Procedure DI-008 of the Spanish metrology center | |
Micrometer for outdoor measurement. Digital display, circular or vernier, d ≥ 0.001 mm | 0 mm a 300 mm | Procedure DI-005 of the Spanish metrology center | |
Case comparator. Digital or analog display, d ≥ 0.0001 mm | 0 mm a 25 mm | Procedure DI-010 for the calibration of mechanical comparators of the Spanish metrology center | |
Tape measure up to 50 m, d ≥ 0.5 mm | 0 m a 50 m | Internal Procedure LM-PC-09, Calibration of Metric Ribbons and Metallic Rules. | |
Ruler up to 2 m, d ≥ 0,5 mm | 0 m a 2 m | Internal Procedure LM-PC-09, Calibration of Metric Ribbons and Metallic Rules. | |
Grade 1 steel gauge blocks | 0.5 mm a 100 mm | NTC 4302 | |
Thick and thick mesh screen | Table 1, ASTM E 11 | ASTM E 11 |
PRESSURE
Instrument to Calibrate | Measurement Range | Standard Document | |
---|---|---|---|
Analog and digital pressure gauges, pressure transmitters with local indicator Class ≥ 0.25% | 0 kPa a 68,95 MPa (0 psi a 10 000 psi) | DKD R 6-1: 2003 |
FORCE
Instrument to Calibrate | Measurement Range | Standard Document | |
---|---|---|---|
Testing machines and / or dynamometers | 1N a 500 kN | NTC ISO 7500 – 1 | |
Compression testing machines | 0,5 kN a 1000 kN | NTC ISO 7500 – 1 | |
TORSION
One of the most recent magnitudes in the metrology laboratory, which seeks to complete the portfolio of products for our customers. Our measurement interval for the provision of accredited services covers the range of 0.5 N.m to 980.665 N.m
Instrument to Calibrate | Measurement Range | Standard Document | |
---|---|---|---|
Torómeters | 0,5 N.m a 980,665 N.m | NTC 5330 |
TEMPERATURE
One of the most important variables for our laboratory, since it has allowed us to develop primary instruments such as the cell of the triple point of water, which was sealed by our team of experts and calibrated in the National Institute of Metrology with highly satisfactory results.
Instrument to Calibrate | Measurement Range | Standard Document | |
---|---|---|---|
Glass thermometer partial and total immersion d ≥ 0,01 ° C | -20 ° C a 250 ° C | NT VVS 102 | |
Analogue bimetallic dial thermometers and temperature recorders (analogues) | -20 ° C a 250 ° C | NT VVS 103 | |
Digital thermometers d ≥ 0.001 ° C | -20 ° C a 600 ° C | NT VVS 103 | |
Resistance thermometers set sensor indicator with RTD sensors | -20 ° C a 600 ° C | DKD-R 5-1 | |
Thermocouple set sensor indicator type K, J, B, E, N, R, S, T | -20 ° C a 600 ° C | EURAMET cg-8 | |
Liquid isothermal media: liquid baths, water baths, dry blocks | -20 ° C a 600 ° C | CENAM Technical Guide for metrological traceability and uncertainty of measurement in thermal characterization of temperature controlled baths and ovens. | |
Isothermal media air: Furnaces, incubators, climatic chambers, refrigerators | -20 ° C a 500 ° C | DKD-R 5-7 |